Split-architecture PSA oxygen system running on DC 24V vehicle power. Independent compressor and adsorption bed modules. Remote monitoring and ON/OFF control from the driver's cab. SUS stainless steel enclosure built for harsh environments.
Unlike integrated units, the O2MOS-7LC physically separates the air compressor from the zeolite adsorption bed. This reduces heat transfer, extends sieve life, and allows independent servicing of each module.
Modular Service Thermal IsolationRuns directly from vehicle or vessel battery systems. Compatible with standard 24V truck electrics and 24V heavy-duty marine or commercial vehicle systems. No inverter required.
DC 24V 20Ah RatedCompact panel-mount controller installed in the driver's cab. Displays real-time O₂ flow rate, output pressure, and DC voltage. Full START / STOP / RESET control without leaving the cab.
Real-Time Monitoring Wired RemoteMarine-grade brushed stainless steel enclosure. Corrosion-resistant, vibration-dampened, and sealed for saltwater spray environments. Far superior to powder-coated steel for marine and fishery applications.
SUS 304 Salt-Spray ResistantGenerates oxygen from atmospheric air. Eliminates high-pressure cylinder logistics, refill schedules, storage requirements, and explosion risks associated with compressed gas cylinders.
No Consumables 24H Auto-RunPrimary application. Runs on the truck's own 24V battery. Continuous O₂ supply to fish tanks during transit — from loading dock to destination, no port refills needed.
DC power makes it ideal for small vessels without AC generators. Keeps live bait and catch oxygenated throughout extended offshore operations on vessel battery systems.
Land-based hatcheries and fish farms with DC power infrastructure. Cab controller can be remounted as a wall panel for central monitoring of O₂ supply.
Press START on the cab controller. The green OPERATE LED lights up and the system starts running.
Each press of SELECT cycles through supply voltage, process pressure, oxygen supply pressure, unit temperature and total running time.
At the externally installed oxygen generator, check the flow meter and pressure gauge by eye, and listen to the machine:
If the controller raises an alarm, read the alarm message shown on the display.
Respond according to the corrective action for that alarm type.
Operating voltage
Process pressureduring operation (machine running normally)
Oxygen supply pressure(air stone)
Oxygen generator temperature
Total running time
Not used(optional)
Low voltage — the supply voltage is below the set threshold.
Oxygen leak, or pressure below the set threshold.
The oxygen generator is not operating — a fault is expected.
| Feature | 40L O₂ Cylinder | O2MOS-7LC ✓ | AC PSA Generator |
|---|---|---|---|
| Power Source | None (pre-filled) | DC 24V | AC 220V required |
| Vehicle / Truck Use | Cylinder only | ✓ Native DC | Needs inverter |
| Refill Required | Daily / every trip | ✓ Never | ✓ Never |
| Remote Cab Monitoring | Not available | ✓ DC O₂CON | Not standard |
| Explosion Risk | High pressure ⚠ | ✓ None | ✓ None |
| Enclosure Material | Steel cylinder | SUS 304 | Coated steel |
| Split Module Service | — | ✓ Independent | Integrated only |
| O₂ Purity | 99.5% | ≥ 90% | ≥ 90% |
DC-native PSA oxygen for trucks, vessels, and off-grid fishery applications. Contact us for a custom quote or technical consultation.